Call for Price
Grundfos Redi Flo 3 22SQE05-110NE Pump Only
Max Depth Maintaining 22 GPM: 110 feet
Horse Power: 3/4 Horse
Voltage AC: 200-240V
Phase: Single
Discharge: 1.5 inch NPT
The Grundfos Redi-Flo3 SQE-NE electrical submersible pump is ideal for the removal of polluted groundwater. Users have the capability to change the pump performance while the pump is installed in the well. Typical applications include: environmental remediation, leachate extraction, total fluids recovery, tank-to-tank transfer, and sampling. Systems are available for your portable or dedicated pumping needs.
General
Well Diameter: Minimum 3 in. (76 mm)
Installation Depth: Maximum 500 ft. (150 m) below static water table
Variable Speed Control: 30%-100% (3,000, 10,700 RPM)
Material: Stainless steel complying with DIN W.-Nr 1.4401 (AISI 316), PVDF and FPM rubber
Electric
Supply Voltage: 1 x 200-240V +6%/-10%, 50/60 Hz PE; 1 x 100-115V
Operation via Generator: The generator output must be equal to the motor P1(KW) +10%
Starting Current: The motor starting current is equal to the highest value stated on the motor nameplate
Starting: Soft-start
Run-up Time: 2 seconds maximum
Motor Protection: The motor is protected against: dry-run, over-voltage, under-voltage, overload, over-temperature and upthrust
Power Factor: PF = 1 Service Factor: 0.5-1.85 HP @ 115V/ 230V; 0.75-2.05 HP @ 230V; 1.0-2.25 HP @ 230V; 1.5-1.65 HP @ 230V
Motor Cable: 2 Wire with ground, Tefzel® Cable Kit (Santoprene® available)
pH Values: 5-9
Liquid Temperature: The temperature of the pumped liquid should not exceed 104°F
Note: If liquids with a viscosity or specific gravity higher than that of water are to be pumped, please contact Enviropump.
Minimum Ambient Temperature: 4°F (-15°C)
Maximum Ambient Temperature: +104°F (40°C)
Maximum Liquid Temperature: 86°F (30°C)